Re: run-time error 429 on Win98

From: Dave Page <dpage(at)vale-housing(dot)co(dot)uk>
To: "'Kobus Nieuwmeijer'" <kobus(at)bitweb(dot)com>, pgadmin-support(at)postgresql(dot)org
Subject: Re: run-time error 429 on Win98
Date: 2002-01-16 11:37:08
Message-ID: FED2B709E3270E4B903EB0175A49BCB104742D@dogbert.vale-housing.co.uk
Views: Raw Message | Whole Thread | Download mbox | Resend email
Thread:
Lists: pgadmin-support

> -----Original Message-----
> From: Kobus Nieuwmeijer [mailto:kobus(at)bitweb(dot)com]
> Sent: 16 January 2002 11:00
> To: pgadmin-support(at)postgresql(dot)org
> Subject: [pgadmin-support] run-time error 429 on Win98
>
>
> Hi,
>
> New here and hope someone can help me. I've installed
> pgadmin2-1_1_76 on a
> Windows 98 with Microsoft Personal Web Server installed and get this
> message when I try to run pgAdmin: run-time error 429 ActiveX
> component
> can't create object.
>
> I tried reinstalling with PWS service stop, and not logging on to MS
> Network, but I still get this problem.
>
> Any suggestions? Thanks in advance for your help,
>

Hi,

We found a problem recently on another Windows 98 machine which was caused
by an incompatible version of riched32.dll in the distribution. This should
be OK in the next release but if you like I can send you the correct
version.

The file normally lives in C:\Windows\System - if you find that it's size is
4K then you have the wrong one.

Regards, Dave.

Browse pgadmin-support by date

  From Date Subject
Next Message Henshall, Stuart - WCP 2002-01-16 13:31:12 Re: run-time error 429 on Win98
Previous Message Kobus Nieuwmeijer 2002-01-16 11:00:27 run-time error 429 on Win98