On 10/12/14 12:28, Strahinja Kustudić wrote:

> * These tests are with the H710p controller set to write-back (WB) and
> with adaptive read ahead (ADRA). I ran a few tests with
> write-through (WT) and no read ahead (NORA), but the results were worse.

That is interesting: I've done some testing on this type of card with 16
(slightly faster Hitachi) SSD attached. Setting WT and NORA should
enable the so-called 'fastpath' mode for the card [1]. We saw
performance improve markedly (300MB/s random write go to 1300MB/s).

This *might* be related to the fact that 16 SSD can put out more IOPS
than the card can actually handle - whereas your 8 S3500 is probably the
perfect number (e.g 8*11000 = 88000 which the card can handle ok).

[1] If you make the change while there are no outstanding background
operations (array rebuild etc) in progress (see
http://www.flagshiptech.com/eBay/Dell/poweredgeh310h710h810UsersGuide.pdf).