Skip site navigation (1) Skip section navigation (2)

Re: odbc and bit-field

From: Hiroshi Inoue <Inoue(at)tpf(dot)co(dot)jp>
To: Jussi J蒿skel臺nen <jussi(dot)jaaskelainen(at)audioriders(dot)fi>
Cc: pgsql-odbc(at)postgresql(dot)org
Subject: Re: odbc and bit-field
Date: 2001-08-01 04:56:45
Message-ID: 3B678C0D.4A918733@tpf.co.jp (view raw or flat)
Thread:
Lists: pgsql-odbc
Jussi J蒿skel臺nen wrote:
> 
> Jussi Jaaskelainen wrote:
> 
> > Hi!
> > Is this bug or is this "bug"...
> > I have table with field type 'bit'  acting as "boolean (true/false)" but
> > thru ODBC driver (in Win-NT 4) it's reported to be "VARCHAR [254]", so
> > it cannot be set to True or False (or 1 or 0)
> >

How are you setting 'Bools As Char' options ?

regards,
Hiroshi Inoue

In response to

Responses

pgsql-odbc by date

Next:From: Jussi JääskeläinenDate: 2001-08-01 10:40:43
Subject: Re: odbc and bit-field
Previous:From: will trillichDate: 2001-07-31 17:00:27
Subject: ODBC connection to Postgres via Macintosh?